AUX R32 C-Series — 9K BTU Heat Pump Mini-Split
Basis of Design: AUX AMAR09HP230V1C
Indoor Unit: AMAR09HP230V1CH
Outdoor Unit: AMAR09HP230V1CO
AHRI Certified Reference Number: 214290015
PRODUCTS
2.1 Equipment
Manufacturer: AUX
Series: C-Series, SEER25
Model: AMAR09HP230V1C
2.2 Cooling Performance
- Rated Cooling Capacity: 9,200 Btu/h
- Cooling Capacity Range: 1,700–13,000 Btu/h
- Rated Cooling Power Input: 675 W
- Moisture Removal: 0.7 kg/h
- Cooling Operating Range: 5°F to 125°F
2.3 Heating Performance
- Rated Heating Capacity at 47°F: 10,000 Btu/h
- Heating Capacity Range: 1,700–15,700 Btu/h
- Maximum Heating Capacity at -5°F: 7,000 Btu/h
- Heating Operating Range: -13°F to 75°F
The manufacturer’s sheet specifically lists 7,000 Btu/h maximum heating capacity at -5°F for the 9K 208/230V unit. amar
2.4 Efficiency
- SEER2: 25
- HSPF2: 10.5
- COP: 3.9 W/W
- EER2: 13.6 Btu/h/W
2.5 Indoor Unit
- Airflow (SH/H/M/L/Q): 355 / 315 / 282 / 255 / 180 CFM amar
- Cooling Sound Pressure: 41 / 36 / 34 / 31 / 26 dB(A)
- Heating Sound Pressure: 41 / 36 / 33 / 29 / – dB(A)
- External Static Pressure: 0 in. w.g.
2.6 Outdoor Unit
- Outdoor Airflow: 1,650 CFM
- Cooling Sound Pressure: 53 dB(A)
- Heating Sound Pressure: 53 dB(A)
2.7 Refrigerant Piping
- Refrigerant: R32
- Gas Line OD: 3/8 inch
- Liquid Line OD: 1/4 inch
- Indoor Drain: 5/8 inch
- Minimum Line Length: 10 ft
- Maximum Line Length: 65 ft
- Maximum Height Difference: 50 ft
- Factory Refrigerant Charge: 28.2 oz
The manufacturer’s sheet identifies R32 as the refrigerant and provides individual factory charges by model. amar
2.8 Electrical
- Power Supply: 208/230V, 1 Phase, 60 Hz
- Minimum Circuit Ampacity (MCA): 9 A
- Maximum Overcurrent Protection (MOCP): 15 A
- Recommended Breaker Size: 15 A
The manufacturer’s table lists the 9K 230V unit under the 208/230V, 1-phase, 60 Hz group. amar